Active rigs:
$17.09 | 4/24/2020 | 04/24/2019 | 04/24/2018 | 04/24/2017 | 04/24/2016 |
---|---|---|---|---|---|
Active Rigs | 29 | 62 | 62 | 48 | 29 |
Two new permits, #37536 - #37536, inclusive --
- Operator: CLR
- Field: Dimmick Lake (McKenzie County)
- Comments:
- CLR has permits for two Kennedy wells in Dimmick Lake, lot 1 section 6-150-96;
- the Kennedy wells are tracked here;
- NP Resources (6): three Elkhorn Ranch Federal permits and three Little Mo Federal permits, all in Billings County;
- XTO (3): three Kenneth permits in Williams County;
- Cobra: a Neru permit in Billings County;
- 36200, drl/A, WPX, Pheasant 33-28HZ, Spotted Horn, t--; cum 74K over 48 days;
- 35990, SI/NC, Equinor, Sam 30-31 3H, Bull Butte, t--; cum --
- 31910, TA/A, Equinor, Sax 25-36F 2TFH, Three Forks B1, Banks, t--; first produced, 9/19; cum 61K 2/20;
- 24050, SI/NC, Petro-Hunt, State 154-94-31C-32-6H; t--; cum --
*************************************
TA
This well was drilled back in 2015. Bottom hole was reached December 22, 2015. The company requested to temporarily abandon the well pending improved economics, sundry form dated September 7, 2017.
In a sundry form dated September 13, 2018, the company requested an extension of the temporary abandonment status for another year.
FracFocus shows this well was fracked 8/17/2019 - 8/28/2019; 10.3 million gallons of water; 90.2% water by mass; friction reducer (petroleum distillates, hydrotreated light, 0.05079; poly (oxy-1,2-ethanediyl), a-tridecyl-2-hydroxy-, branched, 0. 00339, percent by mass
The completion data:
- Bakken, TA, 10/1/2018
- Well status: A, 10/1/2018
Pool | Date | Days | BBLS Oil | Runs | BBLS Water | MCF Prod | MCF Sold | Vent/Flare |
---|---|---|---|---|---|---|---|---|
BAKKEN | 4-2020 | 30 | 11799 | 11743 | 25547 | 37021 | 36153 | 868 |
BAKKEN | 3-2020 | 31 | 12629 | 12848 | 26751 | 38847 | 38128 | 719 |
BAKKEN | 2-2020 | 29 | 12517 | 12339 | 25654 | 38001 | 36708 | 1293 |
BAKKEN | 1-2020 | 29 | 12631 | 12787 | 32199 | 36459 | 34811 | 1648 |
BAKKEN | 12-2019 | 31 | 12616 | 12485 | 36247 | 33323 | 33153 | 170 |
BAKKEN | 11-2019 | 30 | 17090 | 17570 | 36142 | 42600 | 42124 | 476 |
BAKKEN | 10-2019 | 3 | 1787 | 1309 | 3414 | 3293 | 3285 | 8 |
BAKKEN | 9-2019 | 4 | 4728 | 4563 | 12015 | 8043 | 7218 | 825 |
On another note, how precise are these drillers? I find this amazing. From a Statoil letter, dated November 5, 2014:
Statoil ... is fully aware.... that the well path of the lateral portion will be drilled approximately 14' - 39' from the 500' west boundary line until a proposed bottom hole footage call of 250' FNL & 539" FEL has been reached.Wow.
With this proposed well and all future 1280-acre stand-up and laydown units, Statoil will put key emphasis on properly constructing the Bottom Hole Assembly with the correct non-magnetic collar spacing to adjust to the south-north orientation of the proposed wellpath.