Thursday, January 17, 2013

Manufacturing Stage: KOG, The Smokey Wells, Pembroke Oil Field, Section 7-149-98

Note: originally these were the Smokey wells in Pembroke oil field, in sections 7, 8, 17, 18 - 149-97. KOG has Smokey wells in other oil fields. There are some exceptions; some of these Smokey wells, such as Smokey Kinden, are sited in different sections, even different townships. Smokey Kinden, for example: 21-149-98. Over time, I had added other Smokey wells in the general area.



Permits

2014
27447, PNC, Whiting/KOG, Smokey 4-29-32-13H3, Pembroke, 29-149-98,
27446, PNC, Whiting/KOG, Smokey 4-29-32-13H, Pembroke, 29-149-98,

Updates

February 9, 2014: screenshot of the Smokey wells as of today:

July 22, 2013: the Smokey wells have been updated; scroll down. 

April 16, 2013: This is one of two 12-well/1280-arce spacing tests KOG is conducting. KOG is testing 12 wells in one 1280-acre spacing unit: 6 wells targeting the middle Bakken; 3 wells targeting the first bench of the Three Forks; and, 3 wells targeting the second bench of the Three Forks. This is in there Smokey Prospect in McKenzie County, about four miles directly south of Watford City.

Original Post

Today a KOG well in this section came off the confidential list; it is one of four wells on a 4-well pad in the southeast quadrant of that section. #21392 went on DRL status. [Note: IPs and production numbers are updated as they become available.]

So, the other three wells on this 4-well pad will still be on the confidential list.

To this four-well pad, add seven more KOG locations in this same section, in the same quadrant, permits noted in today's daily activity report.

The KOG Smokey Wells

* = Came off confidential; produced for awhile; went back on confidential; re-fracked; huge story; see this post.


PermitStatusOperatorNameCountyFieldTest DateCUMStatus Date
213902,151WLL/KOGSmokey 15-7-6-2H3McKPembroke12/12  221K7/21
213911,500WLL/KOGSmokey 15-7-6-2HMcKPembroke12/12282K7/21
213921,466WLL/KOGSmokey 15-7-19-16H3McKPembroke12/12121K7/21
213931,950WLL/KOGSmokey 15-7-19-15HMcKPembroke12/12189K7/21
247861,321WLL/KOGSmokey 13-7-19-14HMcKPembroke9/13149K7/21
247871,329WLL/KOGSmokey 13-7-19-14H3MMcKPembroke9/1393K7/21
247881,880WLL/KOGSmokey 13-7-19-13HMcKPembroke9/13165K7/21
247891,669WLL/KOGSmokey 13-7-19-13H3McKPembroke9/13150K7/21
247901,859WLL/KOGSmokey 16-7-19-16HMcKPembroke8/13243K7/21
24791708WLL/KOGSmokey 16-7-19-16H3MMcKPembroke8/1357K7/21
247921,867 WLL/KOGSmokey 16-7-19-16HA (30 stages)McKPembroke8/12155K7/21
253612,348 WLL/KOGSmokey 4-15-22-14HMcKPembroke5/15218K7/21
25362
1,933
WLL/KOGSmokey 4-15-22-13H3McKPembroke6/15163K7/21
253632,247 WLL/KOGSmokey 4-15-22-13HMcKPembroke5/15230K7/21
248992,067 WLL/KOGSmokey 2-17-5-2H3McKPembroke10/13253K7/21
249002,328 WLL/KOGSmokey 2-17-5-2HMcKPembroke9/13227K7/21
249011,815WLL/KOGSmokey 2-17-5-3H3McKPembroke9/13175K7/21
249021,949 WLL/KOGSmokey 3-17-20-14HMcKPembroke1/14229K7/21
249031,319 WLL/KOGSmokey 3-17-20-14H3McKPembroke12/1399K7/21
249042,002 WLL/KOGSmokey 3-17-20-14HAMcKPembroke1/14196K7/21
21181IA/182 WLL/KOGSmokey Karen 16-20-17-2HMcKPembroke7/1273K6/21
211821,213 WLL/KOGSmokey Kenny 16-20-17-2H3McKPembroke6/12181K7/21
21183AB/1,638 WLL/KOGSmokey 16-20-32-15HMcKPembroke6/12162K2/19
21184AB/1,738 WLL/KOGSmokey 16-20-32-16HMcKPembroke7/12204K10/18
214392,134 WLL/KOGSmokey Cupcake 14-21-16-3H3McKPembroke11/12271K7/21
214401,404 WLL/KOGSmokey 14-21-3312-14H3McKPembroke11/12175K7/21
214422,125 WLL/KOGSmokey Kinden 14-21-16-3HMcKPembroke11/12280K7/21
214432,036 WLL/KOGSmokey 14-21-33-14HMcKPembroke11/12280K7/21
20516*50 WLL/KOGSmokey 15-22-15-2HSMcKPembroke12/11444K7/21
20596101 WLL/KOGSmokey 15-22-34-15HMcKPembroke1/12288K7/21
237941,283 WLL/KOGSmokey 3-30-18-2H3McKPembroke6/13110K 7/21
237951,829 WLL/KOGSmokey 3-30-18-3HAMcKPembroke6/13159K7/21
237961,259 WLL/KOGSmokey 3-30-31-15H3McKPembroke6/13146K7/21
237971,294WLL/KOGSmokey 3-30-18-3H3McKPembroke6/1398K7/21
255001,543WLL/KOGSmokey 3-17-20-14H3AMcKPembroke1/14172K7/21

2 comments:

  1. So is this where Kodiak is doing the 12-well test? Are other companies doing similar close wellbore testing?

    ReplyDelete
    Replies
    1. CLR:

      http://www.milliondollarwayblog.com/2013/01/clr-with-six-new-permits-in-area-where.html (14 - 34 wells)

      http://www.milliondollarwayblog.com/2013/01/how-does-one-get-34-wells-on-1280-acre.html (14 wells)

      Although not quite the same, Whiting has six or more horizontals/1280-acre spacing unit in much of their Sanish oil field.

      Delete

Note: Only a member of this blog may post a comment.